Technical Specifications For CNG Refueling Stations

The key technologies of CNG refueling stations can be divided into several systems, including the compression system, natural gas pretreatment system, storage system, gas sales system, and control system.

 

Natural Gas Compression System

The natural gas compression system mainly consists of a compressor unit, an intake buffer tank, a cooling system, and a lubrication system. The compressor unit is the most important; it is the heart of the refueling station, and its performance directly affects the reliability and economy of the station's operation. CNG refueling stations generally use reciprocating compressors with high discharge pressure and small displacement. In terms of lubrication methods, there are mainly two types: oil lubrication and oil-free lubrication. For oil-lubricated compressors, an oil removal device should be installed after the final discharge port.

The discharge pressure of compressors used in refueling stations is generally 25 MPa, some are slightly higher, reaching 28 MPa, and a few manufacturers' compressors reach 32 MPa. However, analysis shows that a discharge pressure of 25 MPa is the most economical, reliable, and safe. The inlet pressure range is 0.035–9 MPa, and the compressor discharge capacity can be selected according to different scales, ranging from 16–2000 m³/h, with a commonly used discharge capacity of 200–300 m³/h.

 

Control System

The control system's function is to control the normal operation of the refueling station equipment, monitor the operating parameters of relevant equipment, and automatically alarm or shut down the equipment in case of malfunction. Foreign refueling equipment control systems mostly use PLCs (Programmable Logic Controllers), which offer high reliability, enable fully automated operation, and can also transmit data remotely to the control room for unattended operation, reducing the workload of operators.

 

Storage and Dispensing System

To avoid frequent compressor starts and to provide a gas source when refueling is not required, CNG refueling stations need to be equipped with gas storage devices. A typical design uses a priority control panel to control the sequence of the storage and dispensing systems for efficient refueling and rapid dispensing. Refueling stations usually use a tiered storage method, dividing the gas cylinders into high-pressure... The high-pressure, medium-pressure, and low-pressure cylinder groups are automatically controlled by a priority control panel for their filling and dispensing processes. During filling, the high-pressure group is filled first. When the pressure in the high-pressure group reaches a certain value, the medium-pressure group begins filling. Once the pressure in the medium-pressure group reaches a certain value, the low-pressure group begins filling. Subsequently, all three groups of cylinders are filled simultaneously until the maximum storage pressure is reached, at which point filling stops. During dispensing, gas is first drawn from the low-pressure group. When the pressure in the low-pressure group drops to a certain value, gas is drawn from the medium-pressure group. This process continues until the pressure in the medium-pressure group drops to a certain value. During the initial pressure setting, gas is drawn from the high-pressure group first, then from all three gas cylinders simultaneously, until the pressure in the three cylinders drops to equal the maximum storage pressure of the vehicle's onboard gas cylinder, at which point gas drawing stops. If more vehicles still need refueling, gas is drawn directly from the compressor's exhaust line. After the vehicles have finished refueling, the compressor resumes refueling the three gas cylinder groups in the correct order, then stops. This operating method ensures maximum filling of the gas cylinder groups, maximizing their utilization, and also allows for the fastest refueling speed.