Arrangement of marine fuel tanks on board

Marine fuel tanks are arranged in two ways on ships: on open decks and in enclosed spaces.

 

(1) Tank arrangement on open decks is suitable for ships with suitable space on the main deck, such as oil tankers, chemical tankers, and bulk carriers. Requirements include that the tanks are at least 800mm from the ship's side, the arrangement ensures natural ventilation to prevent the accumulation of escaping gases, and the arrangement ensures that the tanks are not damaged in the event of a collision or grounding. Drip trays should be installed at pipe connections to the tanks where there is a risk of liquid leakage.

 

(2) Tank arrangement in enclosed spaces is suitable for ships without suitable space on the main deck. In this case, the tanks can be arranged in independent compartments, such as container ships and tugboats. The requirements are that the storage tank and fuel pipelines should be at least 800mm away from the side of the ship. The storage tank and related pipelines can be set up in the secondary wall space. The pipelines, valves and equipment connected to the storage tank can be installed in a sealed box. The storage tank space should be ventilated and equipped with fixed fire extinguishing devices, as well as combustible gas and fire detection devices.